Shopping
{{item.quantity}}
تعداد را بنویسید. بیش‌تر از 0 بنویسید. کم‌تر از {{item.product.variant.max + 1}} بنویسید.
{{item.promotion_discount|number}} تومان تخفیف
{{item.total|number}} تومان
مبلغ قابل پرداخت
{{model.subtotal|number}} تومان
submit
Your shopping cart is empty
price
–
–
–
Technical Specifications
Engine Brand: Perkins
Engine Model: 2806A-E18TAG2
Country of Origin: UK
Prime Power: 565 kW / 758 hp
Standby Power: 609 kW / 815 hp
Displacement: 18.1 L
No. of Cylinders: 6 (in-line)
Cooling System: Water-cooled
Governor Type: Electronic
Fuel Consumption (50%): 66 L/h
Fuel Consumption (75%): 97 L/h
Fuel Consumption (100%): 143 L/h
Speed: 1500 rpm
Bore × Stroke: 145 × 183 mm
Compression Ratio: 14.5:1
Injection: Direct
Electrical System: 24 V DC
Lub-Oil Capacity: 62 L
Fuel Tank Capacity: 1100 L
Coolant Capacity: 61 L
Dry Weight: 2050 kg
Technical Specifications – Alternator:
Brand: Stamford
Model: HCI544F
Country of Origin: UK
Prime Power: 620 kVA
Frequency: 50 Hz
Insulation: Class H
Overload Capacity: 110 %
Power Factor: 0.8
Poles: 4
Bearing: 1
Output Voltage: 400/230 V
Speed: 2250 rpm
Main function: Differential protection
Interoperability: SIPROTEC 5 and SIPROTEC 4 line protection devices
Tripping: 3-pole, minimum tripping time 9 ms
Inputs/Outputs: 12 predefined standard variants with
4/4 or 8/8 current/voltage transformers
5–31 binary inputs
8–46 binary outputs
Hardware flexibility: Adjustable I/O structure within the SIPROTEC 5 modular system
Housing width: 1/3 × 19 inches to 2/1 × 19 inches
Application:
Line protection for all voltage levels with 3-pole tripping
Phase-selective protection of overhead lines and cables (single/multi-ended)
Transformers and compensating coils in the protection zone
Ground fault detection in isolated or arc-suppression-coil-ground systems
Communication over fiber, two-wire, or network media
Full interoperability between SIPROTEC 4 and SIPROTEC 5 devices
–
Language selection