Technical Specifications
Rated voltage: up to 15 kV
Rated current: up to 4,000 A
Rated short-circuit current: up to 63 kA
Compact design suitable for standard MV switchgear
High generator-fed fault breaking capability
Special design enabling demanding breaking without additional opening
Engine Specifications
Engine Brand: Cummins
Engine Model: KTA38-G3
Engine Origin: USA
Manufacturing Countries: USA, UK, India
Engine Power: 1050 hp
Emergency Power: 1150 hp
Engine Capacity: 30.5 L
Cylinders: 12
Aspiration: Turbocharged
Cooling System: Water-cooled
Governor Type: Electronic
Fuel Consumption 50%: 94 L/h
Fuel Consumption 75%: 139 L/h
Fuel Consumption 100%: 184 L/h
Engine Speed: 1500 rpm
Bore × Stroke: 140×165.1 mm
Injection System: Direct
Electrical System: 24 V.DC
Oil Tank Capacity: 40.7 L
Cooling Capacity: 114 L
Dry Weight: 4990 kg
Alternator Specifications
Brand: Stamford
Model: HCI634H
Country of Manufacture: UK
Rated Power: 910 kVA
Standby Power: 1000 kVA
Frequency: 50 Hz
Insulation Class: H
Protection: IP23
Overload: 110%
Power Factor: 0.8
Poles: 4
Bearings: 1
Output Voltage: 400/230 V
Rated Speed: 2250 rpm
Generator Coupling Specifications
Prime Power (kVA): 910 kVA
Standby Power (kVA): 1000 kVA
Prime Power (kW): 728 kW
Standby Power (kW): 800 kW
Power range: 0.05–7 kW
Network: Single-phase and three-phase operation
Servo motor: SIMOTICS S-1FL6
Control: PTI, PROFINET, USS, Modbus RTU
Encoder resolution: Up to 21 bits
Features:
One-Button Tuning and real-time auto-tuning
Fast data transfer rates for precise control
Optimized acceleration and braking for smooth operation
Applications: Positioning, conveying, winding, electronic assembly, printing, packaging, material handling
Compact, robust design suitable for industrial environments
System-based for optimized motion control performance
Range of product: MiCOM P64x
Device short name: P641
Relay application: Transformer
Number of inputs: 24 discrete, 7 current input CT...X/5 A and X/1 A
Number of outputs: 24 discrete
Communication port protocol: IEC 60870-5-103, Ethernet, Modbus RTU, DNP3, IEC 61850
Auxiliary supply: 24...48 V DC, 19…65 V, 48...110 V DC, 37…150 V, 40...100 V AC, 32…110 V, 110...250 V DC, 87…300 V, 100...240 V AC, 80…265 V
Network and machine diagnosis type: Fault recording, Event recording, Disturbance recording 75 s
Discrete input voltage: 24...27 V DC universal programmable voltage thresholds, 30...34 V DC universal programmable voltage thresholds, 48...54 V DC universal programmable voltage thresholds, 110...125 V DC universal programmable voltage thresholds, 220...250 V DC universal programmable voltage thresholds
Communication port support: Fiber optic, RS485, RS232
Mounting mode: Panel-mounted
Feeder protection
Extensive protection and control functionality, with sensors or conventional instrument transformers
Ready-made standard configurations for fast and easy setup
Withdrawable plug-in unit design for swift installation and testing
Large graphical display for customizable single-line diagrams (SLDs), accessible locally or via web-based HMI
Extensive lifecycle services
Directional and non-directional overcurrent and earth-fault protection, voltage, frequency, and power measurement
Multi-frequency admittance-based earth-fault protection for higher sensitivity and selectivity
Optional fast fault location for short circuits, earth faults, arc protection, and high-speed outputs
IEC 61850 Editions 1 & 2 support: HSR, PRP, GOOSE messaging, IEC 61850-9-2 LE
IEEE 1588 V2 for high-accuracy time synchronization
Supports Modbus, DNP3, and IEC 60870-5-103 protocols