Caractéristiques Techniques
–
–
–
–
Fonctionnalités entièrement configurables
Matériel évolutif et large éventail fonctionnel
Solution tout-en-un : protection, commande, supervision et monitoring
HMI intégré ou déporté avec boutons programmables
Protection de défaut de terre multifréquence haute sensibilité
Localisation avancée et rapide des courts-circuits et défauts de terre
8 entrées RTD/mA et 4 sorties mA
Prise en charge IEC 61850 Éd.1 incluant GOOSE
Prise en charge DNP3 (TCP/IP) et IEC 60870-5-103
Technical Specifications
–
–
Application: Optimized for three-position disconnectors, switchgear interlocking, suitable for redundant master station, automation via CFC
Control Functions: Number of switching devices limited by I/Os, graphic display of element positions, local/remote switching via key, 4 assignable function keys, measured-value acquisition, signal & command indications, P/Q/cosφ calculations, event logging, switching statistics
Monitoring Functions: Operational measured values, energy metering, time of operation, slave pointer, self-supervision
Communication Interfaces: IEC 61850 Ethernet, IEC 60870-5-103, PROFIBUS-FMS/DP, DNP 3.0, MODBUS, DIGSI 4 service & front interface, time sync via IRIG-B/DCF77
Hardware & Mounting: Operator panel separate if required, key-operated switches for authority, large graphic display with keyboard
Type: Numerical overcurrent and earth fault relay
Models: 7SR1002, 7SR1003, 7SR1004, 7SR1005
Protection functions: Overcurrent (50/51), Earth Fault (50N/51N), Thermal Overload (49), Broken Conductor (46BC), Negative Phase Sequence (46NPS), Sensitive Earth Fault (50SEF/51SEF), CB Fail (50BF), Cold Load Pickup (51C), etc.
Supervision: Trip Circuit Supervision (74TC), Total Harmonic Distortion (81THD)
Control: Lockout (86), CB Control
Power Supply: Universal AC/DC supply
CT Input: 1A / 5A site-selectable
Communication: USB (front), RS485 MODBUS RTU / IEC 103 (rear)
I/O: Up to 6 Digital Inputs and 6 Digital Outputs
Case: Size 4, 4U high, non-draw-out
Applications: Distribution and industrial protection, motor and voltage-based protection
Standard: IEC 60255 compliant
–
Technical specifications
–
–
Application: Optimized for three-position disconnectors, switchgear interlocking, suitable for redundant master station, automation via CFC
Control Functions: Number of switching devices limited by I/Os, graphic display of element positions, local/remote switching via key, 4 assignable function keys, measured-value acquisition, signal & command indications, P/Q/cosφ calculations, event logging, switching statistics
Monitoring Functions: Operational measured values, energy metering, time of operation, slave pointer, self-supervision
Communication Interfaces: IEC 61850 Ethernet, IEC 60870-5-103, PROFIBUS-FMS/DP, DNP 3.0, MODBUS, DIGSI 4 service & front interface, time sync via IRIG-B/DCF77
Hardware & Mounting: Operator panel separate if required, key-operated switches for authority, large graphic display with keyboard
Type: Numerical overcurrent and earth fault relay
Models: 7SR1002, 7SR1003, 7SR1004, 7SR1005
Protection functions: Overcurrent (50/51), Earth Fault (50N/51N), Thermal Overload (49), Broken Conductor (46BC), Negative Phase Sequence (46NPS), Sensitive Earth Fault (50SEF/51SEF), CB Fail (50BF), Cold Load Pickup (51C), etc.
Supervision: Trip Circuit Supervision (74TC), Total Harmonic Distortion (81THD)
Control: Lockout (86), CB Control
Power Supply: Universal AC/DC supply
CT Input: 1A / 5A site-selectable
Communication: USB (front), RS485 MODBUS RTU / IEC 103 (rear)
I/O: Up to 6 Digital Inputs and 6 Digital Outputs
Case: Size 4, 4U high, non-draw-out
Applications: Distribution and industrial protection, motor and voltage-based protection
Standard: IEC 60255 compliant
–
Spécifications techniques
Protection universelle pour moteurs, générateurs et systèmes électriques
Conception modulaire pour flexibilité et extension future
Automatisation avancée pour le contrôle efficace des systèmes électriques
Haute fiabilité dans diverses conditions réseau
Disponibilité locale via fournisseurs de confiance
Interface conviviale pour surveillance, configuration et maintenance
Applications : alimentations, lignes, transformateurs, moteurs, générateurs, banques de condensateurs
Détection et déclenchement sélectif des courts-circuits et défauts à la terre
Protection surintensité directionnelle et non-directionnelle
Protection de distance et différentielle pour lignes et câbles
Protection différentielle de transformateurs (double et multi-enroulements)
Protection moteur contre courts-circuits, surcharge thermique, déséquilibres et fonctionnement bloqué ou à vide
Protection générateur, unités de puissance et moteurs synchrones
Protection banques de condensateurs : déséquilibre de courant, surtension, surintensité, surcharge, différentiel
Protection arcs électriques, surtension et sous-tension
Protection fréquence et variation de fréquence
Protection puissance par tous les modes
Protection différentielle pour transformateurs à 3 et 4 enroulements
Jusqu'à 7 points de mesure supportés (extensibles)
Prend en charge 12 transformateurs de courant et 4 transformateurs de tension
Structure I/O flexible avec jusqu'à 23 entrées binaires et 34 sorties binaires
Protection rapide avec détection des défauts rapide
Modèles d'application disponibles dans DIGSI 5
Conception modulaire pour l'évolutivité du système
Protection contre la défaillance du disjoncteur
–
–
–