Technical Specifications
Main Function: Distance protection for medium- and high-voltage systems
Tripping: 3-pole, minimum tripping time 19 ms
Inputs and Outputs:
4 current transformers
4 voltage transformers (optional)
11 or 23 binary inputs
9 or 16 binary outputs
Hardware:
Modular SIPROTEC 5 platform
1/3 × 19-inch housing, available with large or small display
Conformal coating as standard
Functions:
6-system distance protection
Directional backup protection
Reactance and impedance methods
DIGSI 5 configuration and automation
Benefits:
Reliable Siemens technology
Fast fault detection and isolation
Seamless integration with SIPROTEC 4
Ideal for new or retrofit installations
–
Main function: Differential protection for medium and high voltage lines
Interoperability: SIPROTEC 5 and SIPROTEC 4 line protection devices
Tripping: 3-pole, minimum tripping time 19 ms
Inputs/Outputs: 4 current transformers, 4 voltage transformers, 11 or 23 binary inputs, 9 or 16 binary outputs
Hardware flexibility: 2 different I/O quantity structures available in the 1/3 base module (no 1/6 expansion). Housing width available with small or large display.
Housing width: 1/3 × 19 inches
Standard: Conformal coating
Application: Line protection for all voltage levels; phase-selective protection of overhead lines and cables with single or multi-ended infeed; transformers and compensating coils in protection zone; ground fault detection; serial data communication over optical fiber, two-wire, or network media
Availability: Authorized Siemens suppliers and distributors in Mumbai and across India
Power supply: 48–250 V DC / 100–230 V AC
Line differential protection (87L)
3 phase CT + neutral and residual current inputs
4 VT voltage inputs
40 digital inputs, 16 digital outputs
Withdrawable design with 10-minute backup memory
Ethernet / Serial communication, up to 2 km (fiber optic)
Front protection IP54, panel or rack mounting
Power supply: 48–250 V DC / 100–230 V AC
Measuring inputs: 3 phase CT, 1 standard neutral CT, 1 sensitive neutral CT, 4 VT
Digital I/O: 40 digital inputs, 16 digital outputs
Communication protocols: IEC 61850 Ed.1/2, Modbus TCP, DNP3 TCP, EtherNet/IP
Cybersecurity: IEC 62443-4-2 SL1 compliant
Mounting: Withdrawable, flush or rack mounting
Protection degree: IP54 (with flush mounting frame)
Operating temperature: -40 to +70 °C
Weight: approx. 3.5 kg
Teknik özellikler
–
Koruma Fonksiyonları:
Bara diferansiyel koruması
Seçici bölge kesmesi
Kısa kesme süresi (<15 ms)
Dış arızalara karşı yüksek kararlılık
Faz bazlı ölçüm
48 hücreye ve 12 bara bölümüne kadar yapılandırma
Kesici Arızası Koruması:
Tek fazlı koruma (akımlı/akımsız)
5 çalışma modu
İki kademeli kesme
Telekoruma ile intertrip
Özellikler:
Merkezi veya dağıtılmış kurulum
Kolay genişletilebilir yapı
DIGSI 4 ile kullanıcı dostu yapılandırma
FO (IEC 60870-5-103), Elektriksel (IEC 61850 EN100)
–
–
–