Technical Specifications
Designed for asynchronous three-phase motors with contactor- or breaker-controlled drives
Thermal overload, short-circuit, start-up supervision, negative phase sequence, phase loss, locked rotor, sensitive earth fault, loss of load, and breaker failure protection
Standard configuration adjustable via LHMI
Supports variants with conventional CTs and Rogowski sensor inputs
Universal power supply: 24–240 V AC/DC
Configurable binary inputs/outputs via HMI or communication
Selectable CT rating (1 A / 5 A)
Selectable Modbus RTU and IEC 60870-5-103 protocols
Fast commissioning with test functions
USB front port for retrieving events, fault and disturbance records
Press-fit mounting, compact size, detachable terminals with CT shorting
Extensive self-supervision
Power supply: 48–250 V DC / 100–230 V AC
Measuring inputs: 3 phase CT, 1 standard neutral CT, 1 sensitive neutral CT, 4 VT
Digital inputs / outputs: 40 DI / 16 DO
Communication: IEC 61850 Ed.1 & Ed.2, Modbus TCP, DNP3 TCP, EtherNet/IP
Cybersecurity: IEC 62443-4-2 SL1, role-based access, secure communication
Mounting: Withdrawable, flush or rack-mounted
Display: LCD 128×64 with single-line diagram
Operating temperature: -40 to +65 °C
Protection degree: IP54 (front with frame)
–
Protection for synchronous generators and interconnection points
Compact all-in-one relay with protection, control, monitoring and supervision
Wide generator protection functions: 100% stator earth-fault, generator differential, out-of-step
Advanced interconnection protection compliant with latest grid codes
Optional arc protection and high-speed outputs
IEC 61850 Ed.1 & Ed.2 with HSR/PRP redundancy, GOOSE, IEC 61850-9-2 LE
IEEE 1588 V2 time synchronization
Communication: Modbus, DNP3, IEC 60870-5-103
Withdrawable plug-in unit for quick installation and testing
Large graphical display with customizable SLD and web-based HMI
Extensive life-cycle services
–
Teknik Özellikler
–
–
Motor Markası: Perkins
Motor Modeli: 4016-61TRG3
Ülke Menşei: Birleşik Krallık
Prime Gücü: 2513 hp
Yedek Gücü: 2791 hp
Motor Hacmi: 61,12 L
Silindir Sayısı: 16
Emiş Sistemi: Turboşarjlı
Soğutma Sistemi: Ayrı Radyatör
Regülatör Tipi: Elektronik
Yakıt Tüketimi (50%): 234 L/saat
Yakıt Tüketimi (75%): 344 L/saat
Yakıt Tüketimi (100%): 529 L/saat
Dönüş: 1500 rpm
Silindir Düzeni: V
Silindir Çapı x Piston Yolu: 160x190 mm
Sıkıştırma Oranı: 13.6:1
Enjeksiyon Türü: Direkt Enjeksiyon
Elektrik Sistemi: 24 V DC
Yağ Kapasitesi: 237,2 L
Yakıt Tankı Kapasitesi: 4000 L
Motor Soğutma Kapasitesi: 270 L
Kuru Ağırlık: 5570 kg
Alternatör Markası: Stamford
Alternatör Modeli: PI734H
Prime Gücü (Alternatör): 2500 kVA
Yedek Gücü (Alternatör): 2250 kVA
Frekans: 50 Hz
Yalıtım: H
Koruma: IP23
Verimlilik: 95%
Aşırı Yük Kapasitesi: 110%
Nominal Güç Faktörü: 0.8
Çıkış Voltajı: 400/230 V
Kutup Sayısı: 4
Rulman Sayısı: 1
Devir Sayısı (Alternatör): 2250
–
–
Technical specifications
Designed for asynchronous three-phase motors with contactor- or breaker-controlled drives
Thermal overload, short-circuit, start-up supervision, negative phase sequence, phase loss, locked rotor, sensitive earth fault, loss of load, and breaker failure protection
Standard configuration adjustable via LHMI
Supports variants with conventional CTs and Rogowski sensor inputs
Universal power supply: 24–240 V AC/DC
Configurable binary inputs/outputs via HMI or communication
Selectable CT rating (1 A / 5 A)
Selectable Modbus RTU and IEC 60870-5-103 protocols
Fast commissioning with test functions
USB front port for retrieving events, fault and disturbance records
Press-fit mounting, compact size, detachable terminals with CT shorting
Extensive self-supervision
Power supply: 48–250 V DC / 100–230 V AC
Measuring inputs: 3 phase CT, 1 standard neutral CT, 1 sensitive neutral CT, 4 VT
Digital inputs / outputs: 40 DI / 16 DO
Communication: IEC 61850 Ed.1 & Ed.2, Modbus TCP, DNP3 TCP, EtherNet/IP
Cybersecurity: IEC 62443-4-2 SL1, role-based access, secure communication
Mounting: Withdrawable, flush or rack-mounted
Display: LCD 128×64 with single-line diagram
Operating temperature: -40 to +65 °C
Protection degree: IP54 (front with frame)
–
Protection for synchronous generators and interconnection points
Compact all-in-one relay with protection, control, monitoring and supervision
Wide generator protection functions: 100% stator earth-fault, generator differential, out-of-step
Advanced interconnection protection compliant with latest grid codes
Optional arc protection and high-speed outputs
IEC 61850 Ed.1 & Ed.2 with HSR/PRP redundancy, GOOSE, IEC 61850-9-2 LE
IEEE 1588 V2 time synchronization
Communication: Modbus, DNP3, IEC 60870-5-103
Withdrawable plug-in unit for quick installation and testing
Large graphical display with customizable SLD and web-based HMI
Extensive life-cycle services
–