Teknik Özellikler
Motor Markası: Mitsubishi
Motor Modeli: S12R-PTA2
Menşei Ülke: Japonya
Üretim Ülkesi: Japonya
Nominal Güç: 1165 kW
Acil Durum Gücü: 1285 kW
Toplam Hacim: 49.03 L
Silindir Sayısı: 12
Emiş Sistemi: Doğal
Soğutma Sistemi: Turboşarj – Aftercooler
Regülatör Tipi: Elektronik
Yakıt Tüketimi (50%): 150 L/saat
Yakıt Tüketimi (75%): 211 L/saat
Yakıt Tüketimi (100%): 280 L/saat
Devir Sayısı: 1500 rpm
Silindir Düzeni: Sıralı
Çap × Strok: 170 × 180 mm
Sıkıştırma Oranı: 13.5:1
Yakıt Enjeksiyonu: Direkt
Yağ Kapasitesi: 180 L
Soğutma Sıvısı Kapasitesi: 305 L
Alternatör:
Alternatör Markası: Stamford
Alternatör Modeli: S6L1D-H4
Üretim Ülkesi: Çin
Frekans: 50 Hz
Yalıtım Sınıfı: H
Koruma: IP23
Güç Faktörü: 0.8
Çıkış Voltajı: 400 V
Technical Specifications
Range of Product: PowerLogic P3
Product Type: Protection Relay
Application: Universal
Reference: P3U30-5AAA2BBAB
Mounting Case Size: 30TE
Device Mounting: Flush
Power Supply: 48–230 V AC/DC
Measuring Inputs:
3 × 1/5 A CT Phase Current
1 × 1/5 A CT Residual Current
4 × 100/110 V VT Voltage
Sensors: 0 temperature, 0 arc
Digital Inputs (DI): 16
Digital Outputs (DO): 8 + 1 watchdog
Communication Ports: Front USB 1, Rear RS485 1
Protocols: IEC 60870-5-101, IEC 60870-5-103, DNP3, Modbus RTU, DeviceNet, SPAbus
Cybersecurity: Password protection, port hardening
Protection Functions: Phase overcurrent, directional overcurrent, earth fault overcurrent, directional earth fault, transient earth fault, capacitor bank unbalance, broken conductor, cold load pick-up, H2/H5 detection, breaker failure, SOTF, directional active underpower, fault locator, recloser, phase undercurrent, excessive start time, motor restart inhibition, capacitor overvoltage, negative sequence overcurrent, overvoltage, undervoltage, positive sequence undervoltage, earth fault overvoltage, underfrequency, rate of change of frequency, synchro-check, lockout relay, CT supervision, VT supervision, programmable stages, programmable curve.
Measurement Functions: 3-phase current, zero/positive/negative sequence current, voltage phase to earth/phase, voltage zero/positive/negative sequence, current/voltage ratios, short circuit reactance, fault location, earth fault reactance, frequency, active/reactive/apparent power and energy, cos φ, tan φ, power angle, power factor, voltage/current phasor diagrams, harmonics 2nd & 15th with THD, CB wear monitoring, voltage interruption.
Control Functions: Switchgear control and monitoring, programmable switchgear interlocking, local/remote control, 2 function keys, Easergy SmartApp, web server.
Connections: Screw removable (DI/DO), ring lugs removable (CT), pin removable (VT)
Display: LCD 128x64 pixels (single line diagram & ANSI), 2 customizable keys, 4 LE
Language selection