Teknik Özellikler
Model: 7SR120 Argus
Tür: Yönlü aşırı akım ve toprak koruma rölesi
Girişler: 1/4xI, 3xV
Güç Kaynağı: AC/DC evrensel
Haberleşme: USB (ön), RS485 (arka) – MODBUS RTU / IEC 60870-5-103 / DNP3.0
Ekran: LCD menülü
Montaj: Panel tipi (çekilmez kasa)
Koruma Fonksiyonları:
Düşük Akım (37) • Kırık İletken (46BC) • Negatif Faz Aşırı Akım (46NPS) • Termal Aşırı Yük (49) • Aşırı Akım (50, 51) • Toprak Hatası (50G, 50N, 50SEF, 51G, 51N, 51SEF) • Yönlü Koruma (67) • Yüksek Empedanslı REF (64H) • Alt/Üst Gerilim (27/59) • Negatif Faz Gerilimi (47) • Gerilim Kontrollü Aşırı Akım (51V) • Nötr Gerilim Kayması (59N)
Gözetim Fonksiyonları:
CT Gözetimi (60CTS) • VT Gözetimi (60VTS) • Trip/Kapama Devresi Gözetimi (74T/CCS) • Giriş Akımı Tespiti (81HBL2) • Kesici Arızası (50BF)
Kontrol Fonksiyonları:
Otomatik Yeniden Kapatma (79)
İzleme:
Faz ve Toprak Akımı • Hat Gerilimi • Güç ve Enerji Ölçümleri • Güç Faktörü • Tarihsel Talep Kaydı • PPS/NPS/ZPS Gerilim ve Akımları
Ana Özellikler:
Soğuk Yük Ayarları • 4 Ayar Grubu • 2 Seviyeli Şifre Koruması • Kullanıcı Programlanabilir Mantık • Öz İzleme • Kesici Sayacı • Arıza Kayıtları
Technical Specifications
Model: 7SR119 Argus
Type: Overcurrent and Feeder Protection Relay
Retrofit: Direct replacement for 7SG1114
Power Supply: Universal AC/DC
Communication: USB (front), RS485 (rear) – MODBUS RTU / IEC 60870-5-103
Software: Reydisp for configuration and monitoring
Mounting: Panel / rack
Protection Functions:
Undercurrent (37)
Negative Phase Sequence Overcurrent (46NPS)
Arc Flash Detector (50AFD)
Cold Load Pickup (51C)
Restrictive Earth Fault (64H)
Supervision Functions:
Broken Conductor (46BC)
CT Supervision (60CTS)
Harmonic Blocking (81HBL2)
Trip & Close Circuit Supervision (74T/CCS)
Key Features & Benefits:
Direct retrofit for 7SG1114
Advanced overcurrent & earth fault protection
Arc flash detection & thermal overload monitoring
Easy installation with minimal downtime
Fast delivery and local stock in Mumbai
Spécifications techniques
Protection de défauts à la terre du rotor dans les circuits d’excitation des machines synchrones
Détection des défauts dus au stress mécanique/thermique, vibrations, surintensité ou refroidissement insuffisant
Prévention des seconds défauts à la terre, dangereux pour le rotor
Utile pour les générateurs à bagues collectrices où la poussière de charbon réduit l’isolation
Injection de 100 VCA par condensateurs de couplage vers le rotor
Utilisation avec un relais de défaut à la terre à temps défini