Technical Specifications
–
Current: 3A ... 105A
Main Voltage: 208V ... 600V
Rated Control Supply Voltage: 100 ... 240V AC, 50/60 Hz or 24V AC/DC
Frame Sizes: A, B, C, D
Electrical Sizes: 13
Communication Protocols: Modbus RTU, Profibus, DeviceNet
Certifications: CE, cULus, CCC, EAC, ANCE, C-tick, KC
Key Features: Electrically robust (up to 100 starts/hour), compact design, easy setup and installation, soft start and stop
Power supply: 48–250 V DC / 48–230 V AC
Measuring inputs: 3 phase CT, 1 standard neutral CT, 1 sensitive neutral CT, 4 VT
Digital inputs / outputs: 31 DI / 15 DO
Arc flash sensors: 3 sensors supported
Communication: IEC 61850 Ed.1 & Ed.2, Modbus TCP, DNP3 TCP, EtherNet/IP
Cybersecurity: IEC 62443-4-2 SL1 compliant
Logic engine: IEC 61131 & IEC 61449
Mounting: Withdrawable, flush or rack
Protection degree: IP54 (with flush frame)
–
Five current (I) and four voltage (V) inputs
Flexible current and time grading for all overcurrent protection types
Optional auto-reclose for OHL feeders
Cold load settings, four setting groups, password protection (2 levels)
User programmable logic, self-monitoring, breaker trip counter and timer
Fault, event, and waveform records
Protection Functions: Undercurrent (37), Broken Conductor (46BC), Negative Phase Sequence Overcurrent (46NPS), Thermal Overload (49), Overcurrent (50,51), Earth Fault (50G,50N,50SEF,51G,51N,51SEF), Directional Control (67), High Impedance REF (64H), Under/Over Voltage (27/59), Negative Phase Sequence Voltage (47), Voltage Controlled Overcurrent (51V), Neutral Voltage Displacement (59N), Under/Over Frequency (81)
Supervision Functions: CT Supervision (60CTS), Trip & Close Circuit Supervision (74T/CCS), VT Supervision (60VTS), Inrush Detector (81HBL2), Circuit Breaker Fail (50BF)
Control Functions: Auto Reclose (79)
Monitoring Functions: Primary/Secondary Current Phases and Earth, Line and Phase Voltages, Apparent Power & Power Factor, Real & Reactive Power, Wh & VArh Forward/Reverse, Historical Demand Records, PPS/NPS/ZPS Voltages & Currents
Spécifications techniques
–
–
–
Protection différentielle pour transformateurs à 2 enroulements (87T)
Protection contre la surintensité et la surtension (50/51, 27/59)
Surveillance et diagnostic en temps réel
Interface conviviale et réglages configurables
Ports de communication USB frontal et RS485 arrière
Compatible IEC 61850
Auto-surveillance et enregistrement des défauts
Disponible avec assistance locale à Mumbai, Inde
–
Caractéristiques – Moteur
Marque : Perkins
Modèle : 4008-30TAG3
Origine : Royaume-Uni
Puissance continue : 1270 hp
Puissance secours : 1408 hp
Cylindrée : 30,5 L
Cylindres : 8 (en ligne)
Suralimentation : Turbo AAC
Refroidissement : Eau
Régulateur : Électronique
Conso (50%) : 120 L/h
Conso (75%) : 188 L/h
Conso (100%) : 244 L/h
Vitesse : 1500 tr/min
Alésage x Course : 160 × 190 mm
Compression : 13,1:1
Injection : Directe
Système électrique : 24 V DC
Huile : 153 L
Carburant : 1440 L
Liquide refroidissement : 143 L
Échappement max : 451 °C
Gaz échappement : 196 m³/h
Air refroidissement : 1350 m³/min
Poids : 4217 kg
Caractéristiques – Alternateur :
Marque : Stamford
Modèle : HCI634K
Origine : Royaume-Uni
Puissance nominale : 1110 kVA
Puissance secours : 1220 kVA
Fréquence : 50 Hz
Isolation : Classe H
Protection : IP23
Rendement : 95,4 %
Surcharge : 110 %
Facteur de puissance : 0,8
Pôles : 4
Roulement : 1
Tension sortie : 400/230 V
Vitesse : 2250 tr/min
–
–
–
–
Language selection