Shopping
{{item.quantity}}
تعداد را بنویسید. بیش‌تر از 0 بنویسید. کم‌تر از {{item.product.variant.max + 1}} بنویسید.
{{item.promotion_discount|number}} تومان تخفیف
{{item.total|number}} تومان
مبلغ قابل پرداخت
{{model.subtotal|number}} تومان
submit
Your shopping cart is empty
price
–
–
–
–
–
Technical Specifications:
–
–
–
–
Inputs and Outputs:
4 current transformer inputs (4xI)
4 voltage transformer inputs (4xV)
11 to 75 binary inputs
9 to 41 binary outputs
Hardware Flexibility:
Modular and expandable SIPROTEC 5 system architecture
Scalable I/O configuration (expandable with IO230 module up to 240+ binary inputs)
Housing width: 1/3 × 19" to 2/1 × 19"
Functional Features:
PMU (Phasor Measurement Unit) category support
Standard and extended bay control templates
Double-busbar feeder with switchgear interlocking
Automatic busbar transfer sequence (configurable via CFC blocks)
Supports protection-class CTs for additional protection functions
Applications:
Distribution automation and feeder control
Substation bay automation
Grid synchronization and PMU-based monitoring
System Integration:
Fully compatible with the SIPROTEC 5 ecosystem
Advanced communication and data acquisition
Future-oriented, cost-effective, and modular system design
Spécifications Techniques
–
–
–
Protection différentielle, surintensité, surcharge, défaut de terre, déséquilibre, défaillance disjoncteur
Mesure de courant différentiel/maintien, enregistrement oscillographique
Communication : IEC 61850, IEC 60870-5-103, PROFIBUS, MODBUS, DNP 3.0
Synchronisation IRIG-B / DCF 77
Interface PC pour configuration DIGSI 4
Logique programmable CFC et contrôle local/distant
–
Technical Specifications
Type: Numerical overcurrent and earth fault relay
Models: 7SR1002, 7SR1003, 7SR1004, 7SR1005
Protection functions: Overcurrent (50/51), Earth Fault (50N/51N), Thermal Overload (49), Broken Conductor (46BC), Negative Phase Sequence (46NPS), Sensitive Earth Fault (50SEF/51SEF), CB Fail (50BF), Cold Load Pickup (51C), etc.
Supervision: Trip Circuit Supervision (74TC), Total Harmonic Distortion (81THD)
Control: Lockout (86), CB Control
Power Supply: Universal AC/DC supply
CT Input: 1A / 5A site-selectable
Communication: USB (front), RS485 MODBUS RTU / IEC 103 (rear)
I/O: Up to 6 Digital Inputs and 6 Digital Outputs
Case: Size 4, 4U high, non-draw-out
Applications: Distribution and industrial protection, motor and voltage-based protection
Standard: IEC 60255 compliant
–
Model: 7SR1004 (Argus series – voltage & current based)
Current Inputs: 4
Voltage Inputs: 3
Binary Inputs: 9
Binary Outputs: 6
LEDs: 10
Auxiliary Voltage: 60–240 V AC/DC
CT Input: 1A / 5A (site-selectable)
Communication: Front USB port, Rear RS485 (IEC 60870-5-103 / Modbus RTU / DNP 3.0)
Case Type: 4U high, size 4, non-draw-out
Protection Elements: 4 independent overcurrent elements (50-1 to 50-4) with directional control and transient-free operation
Frequency Protection: 4 under/over frequency elements with Ph-Ph or Ph-N voltage modes
Protection Functions: 46BC, 46NPS, 49, 50, 50N/G, 51, 51N/G, 51C, 50BF, 51SEF, 81HBL2, 50SEF
Supervision: Trip Circuit (74TC), Total Harmonic Distortion (81THD)
Control: Lockout (86), CB Control
Compliance: IEC 60255
–
–
Caractéristiques Techniques
–
Fonctionnalités entièrement configurables
Matériel évolutif et large éventail fonctionnel
Solution tout-en-un : protection, commande, supervision et monitoring
HMI intégré ou déporté avec boutons programmables
Protection de défaut de terre multifréquence haute sensibilité
Localisation avancée et rapide des courts-circuits et défauts de terre
8 entrées RTD/mA et 4 sorties mA
Prise en charge IEC 61850 Éd.1 incluant GOOSE
Prise en charge DNP3 (TCP/IP) et IEC 60870-5-103
–
–
–
Language selection