price
–
–
–
–
–
Technical Specifications
Multi-application coverage with one device
Modular and scalable hardware design
Plug-and-play modules unlocking all functionality
Comprehensive default features including communication
Firmware update support for new functionality
Retrofit adapters for SPACOM replacement
Fully configurable protection relay
12 variants for all basic applications
Withdrawable plug-in unit
Replaceable individual hardware modules
Three supervised arc-sensor inputs
IEC 61850 Edition 2 certified
Power supply: 48–250 V DC / 100–230 V AC
Measuring inputs: 3 phase CT, 1 standard Io, 1 sensitive Io, 4 VT
Digital I/O: 31 DI / 15 DO
Arc flash sensors: 3
Communication: IEC 61850 Ed.1/2, Modbus TCP, DNP3 TCP, EtherNet/IP
Ethernet redundancy: RSTP, PRP
Cybersecurity: IEC 62443-4-2 SL1
Mounting: Withdrawable, flush or rack
Protection degree: IP54 (with frame)
–
Power supply: 24–48 V DC
Measuring inputs: 3 LPCT, 1 CSH neutral current input, 4 LPVT
Digital I/O: 40 digital inputs, 16 digital outputs
Communication protocols: IEC 61850 Ed.1 & Ed.2, Modbus TCP, DNP3 TCP, EtherNet/IP
Cybersecurity: IEC 62443-4-2 SL1 compliant
Logic engine: Advanced programmable logic (IEC 61131 / IEC 61449)
Mounting: Withdrawable, flush or rack mounted
Protection degree: IP54 (with flush mounting frame)
Operating temperature: -40 to +70 °C
Net weight: approx. 3.5 kg
Up to 3 differential protection functions with additional stabilization
5 ground fault differential protection functions
9 × 3-phase current measuring points
5 × 1-phase current measuring points
5 × 3-phase voltage measuring points
20 current transformers, 4 voltage transformers
15–27 binary inputs, 22–38 binary outputs
Housing width: 2/3 × 19” to 2/1 × 19”
Fully modular SIPROTEC 5 design with flexible I/O configuration
Spécifications techniques
–
–
Protection des lignes avec communication différentielle à deux extrémités
Protection sélective par phase séparée, utilisant capteurs ou transformateurs conventionnels
Configurations standard prêtes à l’emploi pour installation rapide et personnalisation
Module enfichable extractible pour installation et tests rapides
Grand affichage graphique pour diagrammes unifilaires personnalisables, accessible localement ou via HMI navigateur web
Services étendus sur le cycle de vie
Protection : surintensité directionnelle/non directionnelle, défaut à la terre, protection et mesure en tension et fréquence
Communication différentielle via fibre optique ou fil pilote, idéale pour transformateur intra-zone
Localisation rapide avancée des défauts en court-circuit et défauts à la terre (optionnelle)
Support IEC 61850 Editions 1 & 2 : HSR, PRP, messages GOOSE, IEC 61850-9-2 LE
IEEE 1588 V2 pour synchronisation temporelle précise
Protocoles pris en charge : Modbus, DNP3, IEC 60870-5-103
–
–