Shopping
{{item.quantity}}
تعداد را بنویسید. بیش‌تر از 0 بنویسید. کم‌تر از {{item.product.variant.max + 1}} بنویسید.
{{item.promotion_discount|number}} تومان تخفیف
{{item.total|number}} تومان
مبلغ قابل پرداخت
{{model.subtotal|number}} تومان
submit
Your shopping cart is empty
price
–
–
–
–
–
Technical Specifications
Current: 3A ... 105A
Main Voltage: 208V ... 600V
Rated Control Supply Voltage: 100 ... 240V AC, 50/60 Hz or 24V AC/DC
Frame Sizes: A, B, C, D
Electrical Sizes: 13
Communication Protocols: Modbus RTU, Profibus, DeviceNet
Certifications: CE, cULus, CCC, EAC, ANCE, C-tick, KC
Key Features: Electrically robust (up to 100 starts/hour), compact design, easy setup and installation, soft start and stop
Power supply: 48–250 V DC / 48–230 V AC
Measuring inputs: 3 phase CT, 1 standard neutral CT, 1 sensitive neutral CT, 4 VT
Digital inputs / outputs: 31 DI / 15 DO
Arc flash sensors: 3 sensors supported
Communication: IEC 61850 Ed.1 & Ed.2, Modbus TCP, DNP3 TCP, EtherNet/IP
Cybersecurity: IEC 62443-4-2 SL1 compliant
Logic engine: IEC 61131 & IEC 61449
Mounting: Withdrawable, flush or rack
Protection degree: IP54 (with flush frame)
–
Five current (I) and four voltage (V) inputs
Flexible current and time grading for all overcurrent protection types
Optional auto-reclose for OHL feeders
Cold load settings, four setting groups, password protection (2 levels)
User programmable logic, self-monitoring, breaker trip counter and timer
Fault, event, and waveform records
Protection Functions: Undercurrent (37), Broken Conductor (46BC), Negative Phase Sequence Overcurrent (46NPS), Thermal Overload (49), Overcurrent (50,51), Earth Fault (50G,50N,50SEF,51G,51N,51SEF), Directional Control (67), High Impedance REF (64H), Under/Over Voltage (27/59), Negative Phase Sequence Voltage (47), Voltage Controlled Overcurrent (51V), Neutral Voltage Displacement (59N), Under/Over Frequency (81)
Supervision Functions: CT Supervision (60CTS), Trip & Close Circuit Supervision (74T/CCS), VT Supervision (60VTS), Inrush Detector (81HBL2), Circuit Breaker Fail (50BF)
Control Functions: Auto Reclose (79)
Monitoring Functions: Primary/Secondary Current Phases and Earth, Line and Phase Voltages, Apparent Power & Power Factor, Real & Reactive Power, Wh & VArh Forward/Reverse, Historical Demand Records, PPS/NPS/ZPS Voltages & Currents
Universal protection for motors and generators
IEC 61850 communication support
Precise overcurrent and short-circuit protection
Robust and reliable for industrial use
Available via authorized suppliers in Mumbai
Ensures maximum operational safety and performance
Spécifications techniques
–
–
Protection différentielle pour transformateurs à 2 enroulements (87T)
Protection contre la surintensité et la surtension (50/51, 27/59)
Surveillance et diagnostic en temps réel
Interface conviviale et réglages configurables
Ports de communication USB frontal et RS485 arrière
Compatible IEC 61850
Auto-surveillance et enregistrement des défauts
Disponible avec assistance locale à Mumbai, Inde
–
–
Language selection