Shopping
{{item.quantity}}
تعداد را بنویسید. بیش‌تر از 0 بنویسید. کم‌تر از {{item.product.variant.max + 1}} بنویسید.
{{item.promotion_discount|number}} تومان تخفیف
{{item.total|number}} تومان
مبلغ قابل پرداخت
{{model.subtotal|number}} تومان
submit
Your shopping cart is empty
price
Technical specifications
Product range: PowerLogic P3
Application: Generator protection
Model reference: REL52126
Power supply: 48–230 V AC/DC
Measuring inputs: 6 CT phase, 3 residual CT, 4 VT 100/110 V
Digital inputs: 12 DI
Digital outputs: 14 DO
Communication ports: USB (front), RJ45 & RS485 (rear)
Protocols: IEC 61850, Modbus TCP/RTU, DNP3, EtherNet/IP
Protection degree: IP54 (front)
Operating temperature: −40 to +65 °C
Compact and versatile all-in-one protection, control, monitoring, and supervision
Motor start-up supervision, loss of load, thermal overload, load jam, and phase-reversal protection
Works with sensors or conventional instrument transformers
Ready-made configurations with customization options
Withdrawable plug-in unit for fast installation and testing
Large graphical display with customizable SLDs, local or web-HMI access
Voltage- and frequency-based protection and measurement
Protection during motor start-up and normal running
Optional arc protection and high-speed outputs
IEC 61850 Ed.1 & Ed.2, HSR/PRP, GOOSE, IEC 61850-9-2 LE support
IEEE 1588 V2 time synchronization
Supports Modbus, DNP3, IEC 60870-5-103
المواصفات الفنية
طلاء مطابق متاح (جديد)
أطراف قابلة للتوصيل للتيار والجهد
عتبات الإدخال الثنائي قابلة للتحديد باستخدام DIGSI (3 مراحل)
قيم محولات التيار الثانوية (1 A / 5 A) قابلة للتحديد باستخدام DIGSI
9 مفاتيح وظيفية قابلة للبرمجة
شاشة من 6 أسطر
البطارية المؤقتة قابلة للتغيير من الأمام
منفذ USB أمامي
2 منافذ اتصال إضافية
مفتاح مدمج للدوائر البصرية الإيثيرنتية ذات التكلفة المنخفضة والمزدوجة
بروتوكولات التكرار في الإيثيرنت RSTP، PRP وHSR لأعلى درجة من التوفر
الاتصال من جهاز إلى جهاز عبر الإيثيرنت باستخدام IEC 61850 GOOSE
مزامنة الوقت بدقة مللي ثانية عبر الإيثيرنت باستخدام SNTP
عدد الإدخالات الثنائية والمخرجات الثنائية قابل للتمديد عبر الاتصال حتى وحدتين SICAM I/O
وظائف الحماية:
حماية من التيار الزائد (50، 50N، 51، 51N)
حماية زمنية ضد التيار الزائد الاتجاهي (67، 67N)
الكشف عن العطل الأرضي الاتجاهي الحساس (67Ns)
عطل الأرض المقيد ذو المقاومة العالية (87N)
مراقبة التيار المنخفض (37)
حماية من التحميل الزائد (49)
حماية من الجهد المنخفض/المرتفع (27/59)
حماية التردد (81O/U)
حماية من فشل القاطع (50BF)
حماية من التسلسل السالب (46)
فحص التزامن (25)
إعادة التشغيل التلقائي (79)
تحديد العطل (21FL)
قفل (86)
وظائف التحكم/المنطق القابل للبرمجة:
أوامر للتحكم في القواطع الكهربائية والمفاتيح القاطعة (الفواصل/المفاتيح المعزولة)
التحكم من خلال لوحة المفاتيح، المدخلات الثنائية، DIGSI 4، أو نظام SCADA
منطق PLC معرّف من قبل المستخدم باستخدام CFC (مثل القفل)
وظائف المراقبة:
القيم المقاسة التشغيلية V، I، f
قيم قياس الطاقة Wp، Wq
مراقبة تآكل القواطع
القيم الدنيا والقصوى
مراقبة دائرة الفصل (74TC)
مراقبة فشل المصهر
8 سجلات للأعطال باستخدام المذبذب
واجهات الاتصال:
واجهة النظام/الخدمة
IEC 61850 الإصدار
Technical Specifications:
Application: Transformers (1-/3-phase), motors, generators, short lines, busbars (up to 7 feeders)
Protection Functions:
Differential protection (phase-segregated)
Sensitive stage for low-fault currents
Fast tripping for high-fault currents
Transformer inrush restraint
Phase and ground overcurrent protection
Overload protection with/without temperature input
Negative-sequence protection
Breaker failure protection (50BF)
Low/high-impedance restricted earth fault (REF) protection
Control Functions:
Commands for circuit-breaker and isolator control
Local/remote control via keyboard, binary inputs, DIGSI 4, or SCADA
User-defined logic with CFC (Custom Function Chart)
Monitoring Functions:
Self-supervision and trip-circuit supervision
Oscillographic fault recording
Continuous differential and restraint current measurement
Transformer thermal monitoring via external thermo-boxes
Communication Interfaces:
Front PC port for DIGSI 4 configuration
IEC 61850 Ethernet, IEC 60870-5-103, PROFIBUS-FMS/DP, MODBUS, DNP 3.0
Service/modem interface, temperature monitoring connection
Time synchronization via IRIG-B / DCF 77
Features:
Integrated thermal replica for winding supervision
Flexible parameterization for various transformer configurations
Proven SIPROTEC 4 platform with more than 1 million units in service worldwide
Technical Specifications
Product range: PowerLogic P3
Application: Generator protection
Model reference: REL52126
Power supply: 48–230 V AC/DC
Measuring inputs: 6 CT phase, 3 residual CT, 4 VT 100/110 V
Digital inputs: 12 DI
Digital outputs: 14 DO
Communication ports: USB (front), RJ45 & RS485 (rear)
Protocols: IEC 61850, Modbus TCP/RTU, DNP3, EtherNet/IP
Protection degree: IP54 (front)
Operating temperature: −40 to +65 °C
Compact and versatile all-in-one protection, control, monitoring, and supervision
Motor start-up supervision, loss of load, thermal overload, load jam, and phase-reversal protection
Works with sensors or conventional instrument transformers
Ready-made configurations with customization options
Withdrawable plug-in unit for fast installation and testing
Large graphical display with customizable SLDs, local or web-HMI access
Voltage- and frequency-based protection and measurement
Protection during motor start-up and normal running
Optional arc protection and high-speed outputs
IEC 61850 Ed.1 & Ed.2, HSR/PRP, GOOSE, IEC 61850-9-2 LE support
IEEE 1588 V2 time synchronization
Supports Modbus, DNP3, IEC 60870-5-103
Caractéristiques Techniques
Fonctionnalités entièrement configurables
Matériel évolutif et large éventail fonctionnel
Solution tout-en-un : protection, commande, supervision et monitoring
HMI intégré ou déporté avec boutons programmables
Protection de défaut de terre multifréquence haute sensibilité
Localisation avancée et rapide des courts-circuits et défauts de terre
8 entrées RTD/mA et 4 sorties mA
Prise en charge IEC 61850 Éd.1 incluant GOOSE
Prise en charge DNP3 (TCP/IP) et IEC 60870-5-103
Language selection